HB-C Series Offline UPS 650 ~ 1000VA

MAIN PARAMETERS

  • Input Voltage Range : 81 – 145VAC or 145-275VAC.
  • Input Frequency : 60 / 50 Hz ( Auto sensing ).
  • Output Voltage : 110V / 120VAC or 220 / 230 / 240VAC.
  • Output Voltage Range: ± 10%.
  • Wave Form( Battery Mode ) :Simulated Sine Wave.
  • Transfer Time : 4 – 6 ms.
Rating Index :

FUNCTIONS

  • Intelligent CPU Control.
  • Optional USB Or RJ45 Port.
  • Auto Restart While AC Is Recovering.
  • Cold Start Function, Off-Mode Charging.
  • Boost And Buck AVR For Voltage Stabilization.
  • Offering LCD Panel For Selection, Multi-Color Panel.
  • The UPS Has Mute Function When The UPS In Battery Mode.
  • The LCD Display Can Be Off When The UPS In AC/ Battery Mode.

MODEL HB-C 650 HB-C 850 HB-C 1000
Capacity 650VA / 360W 850VA / 480W 1000VA / 510W
INPUT
Voltage 110V / 120VAC or 220 / 230 / 240VAC
Voltage Range 81 – 145VAC or 145-275VAC
Frequency 60 / 50 Hz ( Auto sensing )
OUTPUT
Voltage 110V / 120VAC or 220 / 230 / 240VAC
Voltage range ± 10%
Frequency Range ( Battery Mode ) 60 / 50 ± 1Hz
Transfer Time 4 – 6 ms
Wave Form( Battery Mode ) Simulated Sine Wave
BATTERY
Battery Model & Quantity 12V / 7AH x 1 12V / 9AH x 1 12V / 9AH x 1
Charge Time 8 Hours Recover To 90% Capacity
PROTECTION
Full Protection Discharge, Short Circuit And Overload Protection
INDICATORS
LCD Display LCD AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload And Low Battery
ALARM
Battery Mode Sounding Every 4 Seconds
Low Battery Sounding Every Second
Overload Sounding Every Second
Fault Continuously Sounding
INTERFACE
RJ45 / USB 5V ( 2A ) Support Windows XP / Vista, Windows 7/8, Linux, Unix, And MAC
ENVIRONMENT
Humidity 0 – 90% RH @ 0 – 40℃ ( Non-condensing )
Noise Level Less Than 40DB
Dimension ( Mm ) 115 * 115 * 40
N.W. ( Kg ) 5.8 6 6